Select Pressure test stand subcategory

6MPa PTM606A impulse test stand - oil

This testing machine is applied to various types of heat exchangers, oil coolers and other pressure alternating fatigue pulse test, widely used in automobile air conditioning system enterprises, automobile automobile factory technology center, third-party testing center, scientific research institutions and other fields of production inspection, development and research. The testing machine adopts advanced computer measurement and control technology, with high efficiency, good controllability, reliable and durable characteristics, fully meet the test requirements.

 

Features

1, high quality components and advanced control technology combined, high control precision, can achieve trapezoidal wave, sine wave and other waveform;


2, the use of special control software, complete the automatic control of the test process and other functions, temperature control system using PID, real-time control of the test process;


3, overtemperature, overpressure, leakage alarm stop, open the door automatic stop, automatic stop in case of failure and other safety protection functions;


4, the internal structure is reasonable, the layout is beautiful, the use of non-welding pipeline connection, eliminate running and leaking, and easy to install, adjust and maintenance;


5, the use of advanced computer measurement and control technology, the use of special control software, complete the test process of automatic control and other functions, the use of THE United States NI controller acquisition technology, provide data analysis function, meet the test analysis and special test data processing requirements.

Model

PTM606A

Specimen type

Heat exchanger, oil cooler

Standards

QC/T 468-2010, QC/T 828-2010, GB/T 23338-2009, JB/T 8577-2005, JB/T10408-2004,   JB/T10506-2005, JB/T7356-2005,JB/T 6003.2-2010,JB/T8577-2005,TL82012-2009,GMW14192,GMW14319-2012

Pressure range

0.5~6 MPa

Impulse frequency

0.05 ~3Hz

Waveform

Trapezoidal wave, sine wave

Medium

High temperature resistant hydraulic oil, refrigerant oil, silicone   oil

Medium temperature

RT+10~150, or -40~150

Chamber temperature

RT, or -40~150

Specimen connection

Hose connection

Specimen quantity

1~6


youtubideo